Switch 1: This sets the amount of time for
release delay. In the factory set (Off)
position, release delay is set for 15
seconds. Turning the switch On sets a 30
second release delay.
Switch 2 and 3: The combined position of
the 2 switches selects 4 different values
for nuisance delay.
MATRIX #1: Switch 2 Off; Switch 3 Off (factory set): nuisance delay disabled
MATRIX #2: Switch 2 On; Switch 3 Off: 1 second nuisance delay
MATRIX #3: Switch 2 Off; Switch 3 On: 2 second nuisance delay
MATRIX #4: Switch 2 On; Switch 3 On: 3 second nuisance delay
Switch 4: This implements BOCA timed relocking (see Section 4.4). In the factory set (Off)
position, standard relocking from a momentary reset switch is implemented. When the switch is
turned On, 30 second delayed BOCA relocking is set. Under some conditions, local authorities
may require a 45 second delayed BOCA relocking. The standard XDT board does not support
this. Contact the factory to order a modified board with the 45 second feature.
FIG 2: TYPICAL WIRING, EXD SYSTEM
WITH TOUCH SENSE BAR OR TOUCH SENSE PLATE
LED
MK
KEYSWITCH
TSB-3
OR
TSH
MAGNALOCK
NC
C3
NO
NC
C2
NO
NC
C1
NO
XDT BOARD
IF DOORSWITCH
REPLACES KEYSWITCH
IT MUST BE CLOSED
WHEN DOOR IS CLOSED
REMOTE ALARM
RELAY
RED
BLACK
SONA-
LERT
RED
GREEN
RED
GRN
WHT
RED
BLACK
+
V+
RS
IN
FE
BP
LS
+
BLACK
WHITE
BLUE
0V (NEG)
FROM POWER SUPPLY
DIP
SWITCHES
0N
OFF
1
2
3
4
FACTORY SETTINGS SHOWN IN BLACK
BOCA RELOCKING
STANDARD RELOCKING
MATRIX (SEE TEXT)
MATRIX (SEE TEXT)
MATRIX (SEE TEXT)
MATRIX (SEE TEXT)
15 SEC. RELEASE DELAY 30 SEC. RELEASE DELAY