iMXDa/iEXDa QUICK START GUIDE
PRODUCT OVERVIEW
MODEL iMXDa/iEXDa
Holding Force
1200 Lbs 544kg]
Dimensions: Length
12.5" [318mm]
Height 3.63" [92mm]
Depth 2" [51mm]
Dual Voltage 12/24 Volts DC
Current: @ 12VDC 370mA
@ 24VDC 270mA
RECOMMENDED TOOLS
Hammer
Center Punch
Power Drill
Drill bits: 9/64”, 3/16”, 7/32”, 3/8”, and 1/2” (iEXDa)
or 1” (iMXDa) diameters
Wrenches: 7/16” open end (or adjustable), 1/2” box/
open end (or adjustable), 1-1/4” open end
(or 12” adjustable), 3/16” Hex Key (Allen)
and provided 3/32” Hex Key
Pliers, vise grip
Screwdrivers: #1, #2 and #3
Phillips and 1/8” Flat Blade
Masking tape
Fish Tape or Lead Wire
Wire Strippers/Cutter
Multimeter
INSTALLATION
Mounting Configuration
Figure 1 illustrates a common installation on out-swing doors. The lock housing mounts to the
header near the corner opposite the door hinge side. The unit may be mounted horizontally or
vertically. Please use the included product mounting template and the following step-
by-step instructions to successfully install the lock housing and strike.
Figure 1
Typical Section of Installation (iMXDa shown)
To properly install the iMXDa/iEXDa unit, the following conditions should be verified:
The entire mounting area for the lock bracket and housing must be a flat surface.
The installed strike must allow the door to close properly.
The lock (E-laminate) face and strike plate must be aligned so that they are centered.
STRIKE/LOCK ALIGNMENT IS IMPORTANT FOR LOCK SYSTEM STATUS SENSING FUNCTIONS
Sex Bolt & Strike
Mounting Screw
Door Frame & Stop
Door
Strike Plate
Lock Housing
Standard Sex
Bolt
(iEXDa)
Mounting Bracket
Lock Housing
Hardware Pack
SB
-
MXD Sex
Bolt
(iMXDa)
SFP (Not Included)
Mounting Bracket
and Hardware
Rubber Washers
(DPS) Strike
Plate
This Kit Includes
:
Vista de pagina 0
1 2 3 4

Indice de contenidos

Pagina 1 - ASSA ABLOY, the global leader

Securitron Magnalock Corp. Tel 775.355.5625550 Vista Boulevard Fax 775.355.5633Sparks, NV 89434 [email protected]© Copyright, 2010

Pagina 2

PN# 500-22310Page 2 Rev. B, 01/10STEP 1 - MOUNTING THE STRIKE PLATEThe strike plate should be mounted prior to the lock housing. Figure 2 below illust

Pagina 3

PN# 500-22310Page 3 Rev. B, 01/1022.Pull on the assembly (strike) to align and engage the knurled potion of the sex bolt into thehole.23.While keeping

Pagina 4 - Page 4 Rev. B, 01/10

PN# 500-22310Page 4 Rev. B, 01/1011.Assemble the lock back onto the mounting bracket, then using a 3/32” hex wrench tightenthe three (3) set screws al